TPP Series Three Phase Pure Sine Wave Iinverter Charger 6KW-45KW
- Hege útfierkapasiteit oant 45KW
- Unbalance Load akseptabel
- Idle konsumpsje-sykmodus, minder dan 100 W as enerzjybesparring oan is
- DC input voltage 12VDC / 24VDC / 48VDC
- Krêftige oplaadsnelheid maksimum oplaadstroom oant 450A (150A * 3)
- Intelligent kommunikaasje haven RS 232, RS 485, CAN haven
- Avansearre MPPT sinne-oplader controller beskikber
- LED + LCD Display
- Fernbediening opsjoneel (LED of LCD-ôfstân)
- Pure sine wave útfier
- Ultra Low THD, minder dan 3% ûnder folsleine lineêre lading (batterij leech)
- 13Vdc-batterijherstelpunt, wijd foar systemen foar duorsume enerzjy
TPP Series Inverter & Charger | ||||||||||||
Elektryske spesifikaasjes | ||||||||||||
Model | TPP 3KW | TPP 4.5KW | TPP 6KW | TPP 9KW | TPP 12KW | TPP 15 KW | TPP 18KW | TPP 24KW | TPP 30 kW | TPP 36KW | TPP 45 KW | |
Inverter Output | Trochrinnende Output Power | 3000W | 4500W | 6000W | 9000W | 12000W | 15000W | 18000W | 24000W | 30000W | 36000W | 45000W |
Surge Rating (20s) | 9000W | 13500W | 18000W | 27000W | 36000W | 45000W | 54000W | 72000W | 90000W | 108000W | 135000W | |
Yn steat om elektryske motor te starten | 3 hpk | 4,5pk | 6 hpk | 9 hpk | 12 hk | 15 pk | 18 hk | 24 hk | 30 hk | 36 pk | 45 pk | |
Unbalance Load akseptabel | 100% | |||||||||||
DC Input Voltage | 12.0/24.0/48.0 Vdc | 24.0/48.0 Vdc | 48 vdc | |||||||||
Output Waveform | Pure Sine wave / Itselde as ynfier (Bypass-modus) | |||||||||||
Nominale effisjinsje | 89% (Pyk) | |||||||||||
Line Mode Effisjinsje | >95% | |||||||||||
Krêftfaktor | 0,9-1,0 | |||||||||||
Ferbining modus | 3-fase 4-wire systeem + Gnd | |||||||||||
Output voltage rating | 3AC/N 400V/207V | |||||||||||
Output faze voltage | 120/230VAC | 230VAC | ||||||||||
Output Voltage Regeling | ± 10% RMS | |||||||||||
Utfier frekwinsje | 50/60Hz ± 0,3Hz | |||||||||||
Koarte circuit beskerming | Ja, aktuele limytfunksje (Fout nei 60ms) | |||||||||||
Typyske oerdracht Tiid | Typysk 6-8ms, 10ms (Max) | |||||||||||
THD | < 3% (Linear Load) | |||||||||||
DC Ynfier | Nominale Input Voltage | 12.0/24.0/48.0 Vdc | 24.0/48.0 Vdc | 48 vdc | ||||||||
Minimum Start Voltage | 10.5Vdc / 11.0Vdc (*2 foar 24Vdc, *4 foar 48Vdc) | |||||||||||
Lege Batterij Alarm | 10.5Vdc / 11.0Vdc (*2 foar 24Vdc, *4 foar 48Vdc) | |||||||||||
Low Battery Trip | 10.0Vdc / 10.5Vdc (*2 foar 24Vdc, *4 foar 48Vdc) | |||||||||||
High Voltage Alarm & Fault | 16.0Vdc (*2 foar 24Vdc, *4 foar 48Vdc) | |||||||||||
Hege DC-ynfierherstel | 15.5Vdc (*2 foar 24Vdc, *4 foar 48Vdc) | |||||||||||
Low Battery Voltage Recover | 13.0Vdc (*2 foar 24Vdc, *4 foar 48Vdc) | |||||||||||
Idle konsumpsje-Sykmodus | < 100 W as enerzjybesparring oan is | |||||||||||
Kosten | Input Voltage Range | Smel: 96~132VAC / 184~253VAC;Wide: 70~135VAC / 140-270VAC; | ||||||||||
Input Frequency Range | Smel: 47-55±0.3Hz foar 50Hz, 57-65±0.3Hz foar 60HzWide:40-70±0.3Hz foar 50Hz/60Hz | |||||||||||
Output Voltage | Itselde as ynfier | |||||||||||
Charger Breaker Rating (230Vac) | 10A | 10A | 10A | 20A | 20A | 30A | 30A | 40A | 50A | 60A | 80A | |
Charger Breaker Rating (120Vac) | 10A | 20A | 20A | 30A | 40A | 50A | 60A | |||||
Max Charge Rate | 40A*3 | 60A*3 | 80A*3 | 120A*3 | 160A*3 | 100A*3 | 120A*3 | 80A*3 | 100A*3 | 120A*3 | 150A*3 | |
1/2 foar 24Vdc, 1/4 foar 48Vdc | 1/2 foar 48Vdc | 48 vdc | ||||||||||
Krêftfaktor | 0.97 MAX | |||||||||||
Over Charge Protection Shutdown | 15.7V foar 12Vdc (*2 foar 24Vdc, *4 foar 48Vdc) | |||||||||||
Batterij type | Snel Vdc | Float Vdc | ||||||||||
Gel USA | 14.0 | 13.7 | ||||||||||
AGM 1 | 14.1 | 13.4 | ||||||||||
AGM 2 | 14.6 | 13.7 | ||||||||||
Sealed Lead Acid | 14.4 | 13.6 | ||||||||||
Gel Euro | 14.4 | 13.8 | ||||||||||
Iepen Lead Acid | 14.8 | 13.3 | ||||||||||
Calcium | 15.1 | 13.6 | ||||||||||
De-sulfataasje | 15,5 foar 4 oeren | |||||||||||
Ôfstansbetsjinning | Ja.Opsjoneel (LED/LCD) | |||||||||||
Bypass & beskerming | Input Voltage Waveform | Sinuswelle (raster as generator) | ||||||||||
Nominale spanning | 120 Vac | 230 Vac | ||||||||||
Low Voltage Trip | 70V/96V±4% | 184V/154V±4% | ||||||||||
Low Voltage re engage | 75V/100V±4% | 194V/164V±4% | ||||||||||
High Voltage Trip | 130V±4% | 253V/260V±4% | ||||||||||
High Voltage re engage | 135V±4% | 243V/270V±4% | ||||||||||
Max Input AC Voltage | 150VAC | 300VAC | ||||||||||
Nominale ynfierfrekwinsje | 50Hz of 60Hz (Auto detect) | |||||||||||
Low Freq Trip | Smel: 47±0.3Hz foar 50Hz, 57±0.3Hz foar 60Hz Breed: 40±0.3Hz foar 50Hz/60Hz | |||||||||||
Low Freq re engage | Smel: 48±0.3Hz foar 50Hz, 58±0.3Hz foar 60Hz Breed: 42±0.3Hz foar 50Hz/60Hz | |||||||||||
High Freq Trip | Smel: 55±0.3Hz foar 50Hz, 65±0.3Hz foar 60Hz Breed: 70±0.3Hz foar 50Hz/60Hz | |||||||||||
High Freq re engage | Smel: 54±0.3Hz foar 50Hz, 64±0.3Hz foar 60Hz Breed: 68±0.3Hz foar 50Hz/60Hz | |||||||||||
Output Koarte circuit beskerming | Sekering | |||||||||||
Bypass breaker rating (230Vac) | 10A | 10A | 10A | 20A | 20A | 30A | 30A | 40A | 50A | 60A | 80A | |
Bypass breaker rating (120Vac) | 10A | 20A | 20A | 30A | 40A | 50A | 60A | |||||
Oar | Kommunikaasje metoaden | RS232/458/CAN | ||||||||||
Skerm | LED + LCD |